Alcon Argos Biometer

Alcon Argos Biometer

The Faster Solution1-5

  • Measurement capture speed <1.0 sec9‡
    • 1.5x faster scanning speed than IOLMaster* 7001†
    † At 3000 A-Lines/sec as compared to 2000 A-Line/sec for IOLMaster* 700
    ‡ With capture times as low as 0.6 seconds.

The Easier Solution5,6*

  • Angle-to-angle, cornea-to-retina OCT imaging provides real-time guidance for capturing accurate measurements
    • Integrated Alcon Vision Planner with automated and convenient planning software offers sophisticated astigmatic management tools, including an LRI nomogram
    • One-touch software and remote planning options.

The Better Solution1,2,7,8

Advanced SS-OCT technology provided higher acquisition rates than other market-leading biometers1

  • Outperformed IOLMaster* 700 by 41% in grade 4+ cataracts1
    • OCT-enhanced keratometry shown to rival Lenstar*1
    • Uses segmented axial length, improving refractive prediction error, which may lead to better IOL selection7,10

Image Guided Execution

  • Reduces the risk of transcription errors11
    • Provides intra-operative guidance with digital overlays throughout LenSx®procedures based on Vision Planner data11
  • Provides image registration and real time eye tracking to compensate for cyclotorsion. Precisely execute11:
  • Rhexis placement and centration
  • Primary, secondary and arcuate incision

With VERION® Digital Marker LenSx® (DML) integration, surgeons will be able to:

  • Plan arcuate incision using the nomogram integrated into the Vision Planner or personal nomograms added to the planner software12
    • Import surgical plans from the Vision Planner via USB, LAN (Local Area Network) or SMARTCataract to reduce the risk of transcription errors11
  • Ensure precision of arcuate location with image-guided registration to the pre-op image11

Integration with the Digital Marker Microscope (DMM) helps you execute your patient’s surgical plan with digital accuracy.14

Image Guided Integration from the clinic to the OR designed to increase precision and enhance data integrity.11

The Vision Planner sends the surgical plan to the DMM, eliminating transcription errors and allowing surgeons to precisely execute their plan with image-guided precision11.

At the end of the case, the DMM sends surgical data back to the Vision Planner14:

  •  Surgery date 
    •    Procedure type 
    •    Incision width 
    •    Final IOL implanted

An image of the final IOL position at the end of the case can be captured and stored for future reference.12